page 30 RD Instruments
8.6 Personality Module Replacement
Personality modules can be replaced to change the Channel Master
communications protocols (i.e. switch from RS-422 to RS-232).
a. Remove all power to the Channel Master.
b. Remove the I/O cable and place the dummy plug on the I/O cable con-
nector (see “I/O Cable and Dummy Plug,” page 17).
c. Set the transducer assembly (transducer face down) on a soft pad.
d. Remove the housing (see “Housing Assembly Removal,” page 21).
CAUTION. Before handling any Channel Master PC boards, always wear
an earth-grounding static protection strap. The electronics in the Channel
Master are very sensitive to static discharge. Static discharge can cause
damage that will not be seen immediately and will result in early failure of
electronic components.
We assume that a qualified technician or equivalent will perform all of the
following work.
e. With your earth-ground static protection strap on, push the side of the
black plastic board clamp toward the edge of the board far enough so the
Personality Module can be removed (see Figure 21). Pull out the Per-
sonality Module and replace it with the new module. Make sure the
board clamp is securely snapped over the new Personality Module.
f. Replace the housing (see “Housing Assembly Replacement,” page 25).
g. Test the Channel Master (see “Testing Your Channel Master,” page 13).
PUSH BOARD CLAMP
LIFT PERSONALITY MODULE
PUSH BOARD CLAMP
LIFT PERSONALITY MODULE
Figure 21. Personality Module