Channel Master Operation Manual
page 94 RD Instruments
11.5 Correlation Magnitude, Echo Intensity, and
Percent-Good Data Format
BIT POSITIONS
BYTE 7/S 6 5 4 3 2 1 0
1 ID CODE
LSB 00h
2
Correlation Magnitude = 0200, Echo Intensity = 0300, Echo Intensity = 0400
MSB 02 – 04h
3 RANGE CELL #1, FIELD #1
4 RANGE CELL #1, FIELD #2
5
6
RESERVED
7 RANGE CELL #2, FIELD #1
8 RANGE CELL #2, FIELD #2
9
10
RESERVED
(SEQUENCE CONTINUES FOR UP TO 255 BINS)
511 RANGE CELL #255, FIELD #1
512 RANGE CELL #255, FIELD #2
513
514
RESERVED
See Table 21, page 95 through Table 23, page 97 for a description of the fields.
Figure 33. Binary Correlation Magnitude, Echo Intensity, and Per-
cent-Good Data Format
NOTE. The number of range cells is set by the WN-command.