Channel Master CM-6001 Specifications Page 106

  • Download
  • Add to my manuals
  • Print
  • Page
    / 138
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 105
Channel Master Operation Manual
page 100 RD Instruments
For Evaluation Amplitude, Amplitude at the Surface, Standard Deviation,
Max Surface Track and Min Surface Track the following applies: If number
of bursts per ensemble is 1, then this is based on the good pings in the en-
semble. If the number of bursts per ensemble is greater than 1, then this is
based on the output from each burst which could be from individual pings
or from average RSSI data.
Table 24: Surface Track Status Output
Hex Digit Binary
Byte
Field Description
1-4 1,2 VB_STATUS_I
D / Vertical
Beam Status ID
Stores the Vertical Beam Status ID word 4000 (00 40h). LSB
is sent first.
5-12 3-6 Depth (Cor-
rected Surface
Track)
Depth based on surface track output with corrections applied.
Units: 0.1mm
13-20 7-10 Depth (Uncor-
rected Surface
Track)
Depth based on raw surface track output. Units: 0.1mm
21,22 11 Evaluation
Amplitude
Maximum detection filter evaluation amplitude. Units: Counts
23,24 12 Amplitude at
the Surface
Signal amplitude at Surface. Units: Counts
25,26 13 %Good of Sur-
face Track
Percentage of surface track pings in an ensemble burst that
are marked good based on signal strength and a comparison
with burst average depth (see VC command). Units: %
27-34 14-17 STD Surface
Track
Standard deviation of good depths from corrected surface
track pings. Units: 0.1mm
35-42 18-21 Min Surface
Track
Minimum depth of good corrected surface track. Units: 0.1mm
pings
43-50 22-25 Max Surface
Track
Maximum depth of good corrected surface track pings Units:
0.1mm
51-58 26-29 Pressure Depth
Correction
Last good difference between pressure depth and vertical
beam depth ensemble outputs. Units: 0.1mm
59-66 30-33 Depth (Uncor-
rected Pres-
sure)
Depth based on raw pressure output. Units: 0.1mm
67,68 34 %Good of
Depth based on
Pressure
Percentage of corrected pressure measurements good in the
ensemble. Units: %
69-76 35-38 STD of Depth
based on Cor-
rected Pressure
Standard deviation of good depths based on corrected pres-
sure measurements in the ensemble. Units: 0.1mm
77-84 39-42 Min of Depth
based on Cor-
rected Pressure
Minimum depth of corrected pressure measurements in the
ensemble. Units: 0.1mm
85-92 43-46 Max of Depth
based on Cor-
rected Pressure
Maximum depth of corrected pressure measurements in the
ensemble. Units: 0.1mm
Page view 105